Part Number Hot Search : 
2SD1692 KDD25 DC110 1A66C LTC35 CA3045H SFT6693 GP4063D
Product Description
Full Text Search
 

To Download XKH20120 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 S/INT/XKH20120/A/03/05/2002
Relais Statique/Montage sur rail DIN Solid State Relay for DIN rail fixation
* Gamme pret a l'emploi: Relais montable sur rail DIN . * Visualisation de commande par LED. * Sortie AC synchrone. * New generation of SSR for DIN rail fixation. * Control visualization by LED. * Zero-cross AC Output.
page 1 / 2 F/GB
XKH20120
10-32VDC control 10A/ 230VAC output
Application typique/Typical application
AC AC
Ph
1~
celduc
France
76,4
3 1~ 4 2~ 2~
Charge / Load
-
+
29 65
N
25
Caracteristiques de commande (a 20C) / Control characteristics (at 20C) DC Parametres / Parameters Symbol Min Nom Tension de commande / Control voltage Uc 10 24 Courant de commande / Control current (@ Uc nom ) Ic 3 13 Tension de relachement/Release voltage Uc off Resistance interne / Input internal resistor fig.1 Rc 1640 Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Tension assignee Isolement/Rated impulse voltage Uimp 4 000 Isolement entree-sortie / Input-output isolation U 4000 Isolement E-S/semelle/ I-O/ case U 3300
fig. 1 :Caracteristique d'entree / Control characteristic Max 32 18 1 Unit V mA V V VRMS VRMS
21 18 15
Ic (mA)
12 9 6 3 0 0 2 4 68 10 12 14 16 18 20 22 24 26 28 30 32
Uc (V)
Caracteristiques generales / General characteristics Parametres / Parameters Poids/Weight Temperature de stockage / Storage temperature Temperature de fonctionnement / Operating temperature Conditions Symbol Typ. 30 -40/+120 -40/+80 Unit g C C
Proud to serve you
All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis.
r
celduc
e l a i s
S/INT/XKH20120/A/03/05/2002
page 2 / 2 F/GB
Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parametres / Parameters Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crete / Peak voltage Niveau de synchonisation / Synchronizing level Tension d'amorcage / Latching voltage Courant nominal / Nominal current Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de frequence / Operating frequency range dv/dt etat bloque / Off state dv/dt dI/dt maximum non repetitif/ Maximum di/dt non repetitive I2t (<10ms) EMC Test d'immunite /Conducted immunity level: with external VDR EMC Test d'immunite /Conducted immunity level : with external VDR Conformite / Conformity Homologation / Approbal Conditions Symbol Typ. Unit Ue 230 V rms Uemin-max 12-280 V rms Up 600 V Usync 12 V Ua 8 V Ie 16 (*) A rms Itsm 160 A Vd 1,6 V Ilk 1 mA Iemin 5 mA ton max 10 ms toff max 10 ms f 10-440 Hz dv/dt 500 V/s di/dt 50 A/s I2t 128 A2s 2kV criterion A with external VDR 2kV criterion A with external VDR / pr EN61810-xxx UL pending
Ie nom tp=10ms (Fig. 3) @ Ie nom @Ue, 50Hz Uc nom DC ,f=50Hz Uc nom DC ,f=50Hz
IEC 1000-4-4 (bursts) IEC 1000-4-5 (shocks) EN60947-4-x and 5-1
* : / Limite par le radiateur et le circuit imprime / limited by the heatsink and the printed circuit board
Fig.2 Caracteristiques thermiques / thermal curves :
I max = f(Ta)
26 24 22 20 18 16 14 12 10 8 6 4 2 0 Ventilation forcee avec temperature du dissipateur limitee a 85C./ Forced air cooling with heatsink temperature 85C max
I (A)
Convection naturelle/ Convection cooling
0
10
20
30
40
50
60
70
80
90
100
Ambient temperature ( C)
Precautions : * Les relais a semiconducteurs ne procurent pas d'isolation galvanique entre le reseau et la charge. * Prevoir un varistor externe en parallele sur la sortie : taille mini : 14mm
Cautions : * Semiconductor relays don't provide any galvanic insulation between the load and the mains. * Use a VDR across the output : minimum size : 14 mm
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19


▲Up To Search▲   

 
Price & Availability of XKH20120

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X